• Home
  • Production Facility
  • Contact Us
  • Products  
     

    CCV Line

     

    Main Features:

     

    No.

    Commodity

    Qty

    A

    35kV   Triple-layer Co-extrusion Dry-cure CCV Line (6+2+9)

    1set

    B

    Cable partial   discharge test system

    1set

    C

    Nitrogen system

    1set



     
    Main technical specification:
     

    Voltage class:XLPE: 6~35kV

    Conductor cross section: Cu: 35~630 mm2

                           Al: 50~800 mm  

    Max. Weight of cable: 10 kg/m

    Outer diameter of cable: 75 mm

    Wall thickness:

    65 extruder for inner layer: 0.5~2.0 mm

    150 extruder for insulation layer: 2.5~10.5  mm

    90 extruder for outer layer: 0.5~2.0 mm

    Length of vulcanizing tube: 120m

    Heating section: L=36m; 6m6

    Pre-cooling section: L=12 m;6m2

    Water cooling: L=54m; 6m9

    Needed area of main platform (LW): (LW)24m18 m

    Height of 3-platform: 10m

    Needed length of workshop (premises): 135 m

    Nitrogen gas:

    Pressure: 2.0~2.5 Mpa

    Purity: 99.5 %

    Consumption: 0.4~1.8 m3 /h

    Volume of N2 tank: 5 m3 

    Cooling water:

    Pressure: 0.2~2 Mpa

    Circulation consumption: 12.5m3 /h

    Compressed air:

    Pressure: 0.6~0.8 Mpa

    Standard consumption: 0.8 m3 /h

    Installed capacity: 750 kVA

    Two power incoming lines: (3185 mm2 , 3240 mm2)


     
    Products photo:
     



     
    Video: